FM9 Auxiliaries

FM9 Auxiliaries

The electrical accessories of this series of circuit breakers are the auxiliary functional components specially designed by our company for FM9 series circuit breakers. In the light circuit, household and building, different electrical accessories and GYM9 series circuit breakers can be selected according to the need, which can realize remote control, circuit breaker status indication, alarm signal, under-voltage and over-voltage protection function.

AU9-AL9

ModelAU9AL9
TypeAuxiliary ContactAlarm Contact
StandardIEC/EN 60947-5-1IEC/EN 60947-5-1

Function




Indicating the On/off state of


Circuit breaker

Sending signal at the time of fault tripping of Circuit breaker


On the front panel, there is mechanical indication which can indicate fault tripping

Application




Distant indication of


Circuit breaker state

Sending signal at the time of fault tripping
Voltage  UeAC   230/400VAC   230/400V
DC   120VDC   120V
Rated frequency50/60Hz50/60Hz
Red Mechanica indicationNoyes
Test functionNoyes
Working  Current


230V AC  6A230V AC  6A

400V AC  3A400V AC  3A

120V DC  1A120V DC  1A
Contact Number1NO/NC1NO/NC
Working  temperature-35~+70℃-35~+70℃
Wiring Diagram

 

SH9-UV9-OV9

ModelSH8UV9OV9UV9+OV9


 

TypeShunt ReleaseUndervoltage trippingOvervoltage tripUnde&Over-voltage of Single-phase


 

StandardIEC/EN 60947-5-1IEC/EN 60947-1


 

 

IEC/EN 60947-1


 

 

IEC/EN 60947-1


 

 

Function






When it gets signal, it triggers the circuit breaker to trip.When power voltage lowers( 35%~70%Un), it makes circuit breaker trip; When power is not supplied normally, it prevents circuit breaker from reconnecting to the circuit.


 

Monitor voltage between phase line and neutral line. When voltage rises( for example, neutral line is broken) , it triggers circuit breaker to trip.It has function of over-voltage release, and function of making circuit breaker trip when power voltage lowers.


0.2 S time delay prevents the temporary lowering of voltage from causing mistrip.rated tripping voltage range: 280vac±5%.Rated tripping voltage range: 280vac±5%.


Rated under-voltage tripping range: 55~160v.

Application






Distant control can achieve emergency breaking.Prevent machine from restarting without control signal, ensuring safety.Prevent over-voltage from damaging circuit and equipment.Prevent over-voltage and under-voltage from damaging circuit and equipment.
Voltage  UeAC   230/400V


AC   48V

AC   12/24V

AC   230/400V


 

AC   230/400V


 

AC   230/400V


 

DC   120V


DC   48V

DC   12/24V




Rated frequency50/60Hz

50/60Hz
Test functionNoyesyesyes
Working  temperature-25~+70℃

-25~+70℃