FB10 epoxy resin cast dry-type transformer

FB10 epoxy resin cast dry-type transformer

Medium Voltage Vacuum Cast with Epoxy Resin Transformer for General Power Distribution

Product Description

medium  voltage vacuum cast with epoxy resin transformer for general power distribution 


 )CH[Q3MNTWQNJW[GC)(BN{C.png

SCB10 Three Phase Dry Type Power Transformer

FB10 epoxy resin cast dry-type transformer is an upgrade product of SCB9. SCB10 series products features significant high mechanical strength, high electrical strength, high heat resistance and low loss, low noise, low partial discharge. So FB10 dry-type transformer is environmental protection products for new generation of urban power grid update, and is the mainstream product in the current transformer market. It is especially suitable for commercial center, airport, high building, chemical plant, nuclear power station, ship and other important places requiring fire prevention, explosion-proof and moisture-proof.


Structural features
 1. The iron core is made of high-quality cold-rolled oriented silicon steel sheet, the surface is specially treated with protective resin, and full-inclined seam lamination structure is adopted.
 2. The low-voltage coil is of foil winding structure made of high-quality steel foil. The high-voltage coil is of layer structure formed by vacuum epoxy casting technique. Transformers with this type of winding shows low partial discharge compared with similar product ;
 3.This model features high mechanical strength, strong short-circuit resistance, good dust-proof and anti-fouling performance. Its service life is longer than another dry transformer.
 4. The product's beautiful stainless-steel shell is durable and can provide better protection for the electrified parts of the transformer. It works well outdoors.
 5. With excellent moisture-proof and corrosion-resistant performance, the product is safe, fire-proof and pollution-free. It's especially suitable for working in extremely harsh environmental conditions, and can restart without dry treatment after shutdown.
 6. Good heat dissipation performance and strong overload capacity enables it operate with higher capacity when forced air cooling.


Transformer Structure 


 UR1J)38$52Y)W$BZ$E4)5%X.png

Technical parameters

Rated Capacity (kVA)TypeVector GroupNo-load
current (%)
No-Load
Loss(kW)
Load loss (kW)short circuit impedance
(%)
30FB10-30Yyn02.50.1950.714
50FB10-502.20.2750.95
80FB10-802.10.3751.385
100FB10-1001.90.4051.58
125FB10-1251.80.4751.895
160FB10-1601.80.552.14
200FB10-2001.60.632.54
250FB10-2501.50.732.77
315FB10-3151.40.893.485
400FB10-4001.40.994.01
500FB10-5001.31.1754.91
630FB10-6301.31.365.91
630FB10-630Yyn0
or
Dyn11
1.21.3155.9956
800FB10-8001.21.546.99
1000FB10-10001.11.798.17
1250FB10-12501.12.1159.75
1600FB10-160012.4811.8
2000FB10-20000.93.3614.535
2500FB10-25000.84.0517.27

Our workshop 


 LCT_36RG1UH2%@]}S[V5K9Q.png


 

Relevant Products